(9) Data Hold
Press the “D.HOLD” button on the meter to enter the data hold mode and press this
button again and the meter exits the data hold mode.
(10) Auto Power Off and Disable
1. When the meter has been turned on for 15 minutes without any action from the users,
the meter will automatically turn itself off.
2. To disable the Auto Power Off function, press any button when the meter is on or
switch the selector switch.
4. Care and Maintenance
4-1. Caring for Your Multimeter
Your digital multimeter is an example of superior design and craftsmanship. The following
suggestions will help you care for the multimeter so you can enjoy it for years.
1. Keep the multimeter dry. If it gets wet, wipe it dry immediately. Liquids can contain
minerals that can corrode electronic circuits.
2. Use and store the multimeter only in normal temperature environments. Extreme
temperatures can shorted the life of electronic devices, damage batteries, and distort
or melt plastic parts.
3. Handle the multimeter gently and carefully. Dropping it can damage the circuit boards
and case and can cause the multimeter to work improperly although the holster can
provide enough protection.
4. Keep the multimeter away from dust and dirt, which can cause premature wear of
parts.
5. Wipe the multimeter with a damp cloth occasionally to keep it looking new. Do not
use harsh chemicals, cleaning solvents, or strong detergents to clean the multimeter.
6. Use only fresh batteries of the required size and type. Always remove old or weak
batteries. They can leak chemicals that destroy electronic circuits.
4-2. Maintenance
9V Battery Replacement
1. Make sure that the instrument is not connected to any external circuit. Set the
selector switch to the OFF position and remove the test leads from the terminals.
2. Remove the screws from the bottom case and lift the case. Remove the spent battery
and replace it with a battery of the same type.
Fuse Replacement
Remove the screws from the bottom case and lift the case. Replace the fuse with the
same type and rating: 5 x 20mm 0.5A/250V fast-blow fuse or 5 x 20mm 10A/250V
fast-blow fuse as the replacements.
Elenco
TM
Electronics, Inc.
150 W. Carpenter Avenue
Wheeling, IL 60090
(847) 541-3800
http://www.elenco.com
OPERATOR’S
INSTRUCTION MANUAL
M-2795
DIGITAL MULTIMETER
Copyright © 2003 Elenco
TM
Electronics, Inc.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - DIGITAL MULTIMETER

(9) Data HoldPress the “D.HOLD” button on the meter to enter the data hold mode and press thisbutton again and the meter exits the data hold mode.(10)

Page 2 - ! WARNING !

1. Safety InformationTo ensure that the meter is used safely, follow all of the safety and operationinstructions in this manual. If the meter is not

Page 3 - 3. Operation

3. OperationWARNING1. When measuring voltage, be sure that the instrument is not connected or switched tothe resistance range. Always ensure that the

Page 4 - 2. Specifications

2. Specifications2-1. General SpecificationsDisplay 3 3/4 digit LCD with a max. reading of 4000.Range Control Manual range control.Polarity Automatic

Comments to this Manuals

No comments